Thank you for purchasing a OneSpace Manager Server product. Our newest release of Manager Server contains several enhancements and new features. Please see the "Update Training" document for a list of new features.
This document contains information that may not be included in the documentation for Manager Server 2007 (15.50C). Please read this document before installing the product for any last minute information.
Click a link below for more information.
After installing Oracle 10g on a Windows system, you MUST reboot the computer before installing the Manager
Server Database Server. Failure to do so may cause an ORA-12560 error: TNS protocol
error, which hangs the installation. Recovery may not be possible.
This affects all versions of CoCreate OneSpace Manager Server supporting Oracle 10g.
Beginning with OneSpace Manager 14.20, the installer has been improved to automatically detect whether an upgrade or a new installation is required. The detection process uses a client to connect to the database and that client is unable to connect to unsupported versions (like WorkManager 5 and WorkManager 6). Customers that need to upgrade from those very old versions will need to upgrade in two steps, from the old version to an intermediate supported version (like OneSpace Manager 13), then from that intermediate version to Manager Server 15.00.
If you upgrade to Manager Server 15.50C, the Created At / Created By attributes on a Masterdata are not correctly updated when you release.
You need to manually add the DT_REL_ATTR_ACL Access Control List on the Created At / Created By attributes.
In Annotation revisions 14.50 and earlier, the default PDF generation settings used a default pen size of 0. At 15.00, the default pen size changed to 0.5, making it difficult to see all of the lines when you have scales of 1:2 or smaller.
The plot attributes can be modified in Annotation by creating a custom style, which can then be sent to Model Manager to use when creating a PDF. See the Model Manager Customization Guide, "PDF customization" for more information.
WMDT_DIR. Design Data Management needs:
WMDT_DIR=C:\Program Files\CoCreate\OneSpace Manager 2007\desktopDrawing Manager needs:
WMDT_DIR=C:\Program Files\CoCreate\Shared\Model Manager 2007\desktopCustomers who need to run both Drawing Manager and Design Data Management on the same computer will need to change the values of the
WMDT_DIR environment variable when they switch between Drawing Manager
and Design Data Management. When the WMDT_DIR value is changed, Drafting
must be restarted.
Drawing Manager requires that the environment variable
WMDT_PROFILE is set to EXPERT.
LET Awm_val_store_old_version "STORE_270 ANNO" This macro makes it possible to store a Drawing 2D into MI format 2.70 with Annotation info (MI File Creating System). (Useful for users using Drafting and Annotation synchronously)
LET Awm_val_store_old_version "STORE ANNO" This macro makes it possible to store a Drawing 2D into MI format 2.80 (current) with Annotation mode. (Drafting <> Annotation's users)
"Show Alternative Versions" is a new option inside of the Design Data Management function that is new to the "Reload" option within OneSpace Modeling.
"Show Alternative Versions" expands the "Reload" option with the possibility of reloading any version of elements from Manager Server.
Use of the New Version Replace functionality will cause previous versions of thumbnails to no longer be visible. Use of the functionality will also interfere with replication of versions when using Global Data Management.
The SAP Process Adapter can only be installed as part of the Windows installation from the CDROM. You must install the Design Data Management personality to obtain the macros for the SAP Process Adapter.
Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Software clause in DFARS 252.227-7013. Rights for non-DOD U.S. Government Departments and Agencies are as set forth in FAR 52.227-19(c)(1,2).
The information contained in this document is subject to change without notice. CoCreate makes no warranty of any kind with regard to this information, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. CoCreate shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
A copy of the specific warranty terms applicable to your CoCreate product and replacement parts can be obtained from your local Sales and Service Office.
Copyright © 2001-2007 CoCreate Software GmbH. All Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under copyright laws.
UNIX ® is a registered trademark of the Open Group.
Windows ® is a U.S. registered trademark of Microsoft Corporation.
eDrawings™ is a trademark of SolidWorks Corporation.
XVLŪ is a trademark of Lattice3D.